  NEUTRAL GROUNDING RESISTORS  
 
COMMON REASONS for USING NEUTRAL GROUNDING RESISTORS

. Reducing single phase fault currents which occur in M.V. electrical networks to prevent damages on transformers and generators,
. Reducing temporary over voltages occurred by braking instantaneous fault current,
. Providing long-life for switchgear,
. Reducing step voltages to a harmless level for staff.
 
 


 
FEATURES

. Stainless-steel resistor elements.
. Current transformer included (EN 60044-1).
. Bolted resistor element connections instead of welded connections in order to be able to assemble spare parts on site immediately.
. Typically, RAL 7032 (and others) epoxy-based (70 micrometer thickness) polyester electrostatic powder paint for galvanized enclosure element to provide maximum resistance against corrosion.
. Typically, 2 mm hot dip galvanized steel enclosure.
. High thermal capacity to absorb high currents.
. High altitude ratings.
. Custom made lifting eyes provide secure lifting.
. Rugged shock-resistant construction.

 

elastimoldbushing
 

TECHNICAL SPECIFICATIONS

   
 

 OPERATION VOLTAGE

 Up to 72 kV line to line systems

 RATED CURRENT (A)

 Up to 5000

 AMBIENT TEMPERATURE (°C)

 < 55

 RESISTANCE ALLOY

 Stainless - steel

 PROTECTION DEGREE

 IP 23 (outdoor) and others

 STANDARDS

 IEEE 32, EN 60137, EN 60529, EN ISO 1461, EN 60298 , EN 60273, EN  60071, EN 60060

       
 

Neutral Grounding Resistors are used for resistance grounding of industrial power system. They are generally connected between ground and neutral of transformers, generators and grounding transformers. Neutral Grounding Resistors are used in order to limit maximum fault current to a value which will not damage the equipment in the power system, yet allow sufficient flow of fault current to operate protective relays to clear the fault. Although it is possible to limit fault currents with high resistance Neutral Grounding Resistors, earth short circuit currents can be extremely reduced. As a result of this fact, protection devices may not sense the fault. Therefore, it is the most common application to limit single phase fault currents with low resistance Neutral Grounding Resistors to approximately rated current of transformer and / or generator.

Example : A 10000 kVA 13,8 kV generator's rated current is 419 A . Therefore, 400 A or 500 A Neutral Grounding Resistor is generally considered as suitable for that application.

Hilkar resistors are designed to absorb a large amount of energy without exceeding temperature limitations defined in IEEE 32. Neutral Grounding Resistors Hilkar manufacture can be used for indoor and outdoor and the neutral point is connected with a porcelain bushing or with a (minimum cross-section = 70 mm2 copper or 95 mm2 aluminum) high voltage (XLPE) cable from the bottom. The most common protection degree preferred for Neutral Grounding Resistors is IP 23 as it allows the resistor elements to cool easier and they can be used both at sea shores and deserts because the resistor elements are completely stainless steel and does not get affected by extreme conditions. Neutral Grounding Resistors are sent with MAINTENANCE AND INSTALLATION GUIDELINES. In MAINTENANCE AND INSTALLATION GUIDELINES, recommended relay settings for each Neutral Grounding Resistor are stated as well. Hilkar provides complete technical assistance in order to meet your specifications or site conditions.

       
 
neutralearthingresisto
       
 

ENCLOSURE FEATURES

              
  • 2 mm hot dip galvanized steel enclosure.
  • Epoxy-based RAL 7032 (or RAL 70XX) polyester electrostatic powder paint provides maximum protection.
  • Solid top cover sloped to prevent water accumulation.
  • Custom made lifting eye bolts for secure lifting.
  • Front cover for easy access to connection and inspection.
  • Corrosion resistant nameplate.
       
 

OPTIONS

              
  • Elevated support stands are provided for ground clearance and safety.
  • Custom made AISI 304 stainless steel enclosures are available.
  • Different paint types are available.
  • Specially designed units for hazardous and extreme locations.
  • Voltage transformers are mounted inside the resistor enclosure.
  • Protection Relays are available.
  • Porcelain entrance bushings can be mounted on top or on the side of Neutral Grounding Resistors.
  • Motorized or manual single pole disconnector switches, voltage transformers, surge arresters and heaters in the Neutral Grounding Resistors.
       
 
ROUTINE TESTS

          . Measurement of insulation resistance between enclosure and resistor.
          . Withstand test of dielectric strength at network frequency for one minute.
          . Measurement of total DC resistance.
          . Insulation test of resistor blocks.
          . Galvanize thickness test.
          . Paint thickness test.
  neutralearthingresistorneutralearthingresistor     GENERATOR NEUTRAL CUBICLE and NEUTRAL GROUNDING RESISTOR 2500 A 6,3 kV  
 

TYPE TESTS (on demand)

  • Temperature rise test
  • Protection degree test
  • Impulse voltage test (1,2 / 50 µs)
  • Measurement of AC resistance
  • Seismic test

 

SELECTION DETAILS

  • System Voltage
  • Line to Neutral Voltage
  • Desired Current Rating
  • Desired Resistance Level
  • Maximum Time ON (seconds)
  • Bushing Entry or Cable Entry
  • Current Transformer Ratio (if applicable)
  • Disconnector Switch (if applicable)
  • Special Options (if applicable)
       
 
  * Height of bushing    
       
 


Examples of
grounding
the neutral
point through
the resistance

3D design
of Neutral
Grounding
Resistors

       
 

Examples of providing artificial neutral point if it is impossible to reach the neutral point of the source or the connection is delta.

       
       