SHUNT REACTORS
SHUNT REACTORS
|
|
Shunt reactors are used in order to compensate capacitive reactive power generated by long and lightly transmission lines, thus allowing the flow of more active power through the system. Shunt reactors are normally connected to the tertiary winding of the main transformer.
In high power and high voltage systems, shunt reactors should be used with RC filters because in such systems switching transient voltages are extremely high and that's why switching devices may be damaged.
|
ADVANTAGES
Perfect mechanical strength to withstand high short-circuit forces.
Limited temperature rise enables longer lifetime.
Special surface protection against UV and pollution class IV areas.
Maintenance-free design
STANDARD EN 60289 or depending on customer requirements.
|
|
|
|
FEATURES
Air core and iron core
Dry type
Side by side, delta or vertical arrangement depending on space availability for air core reactors
Outdoor and indoor
Single phase or three phase
Enclosures are available on demand
Elevated support stands are available
Aluminum or copper winding
RAL 7032 or other colors
- 40 ºC / + 55 ºC ambient temperature range
F class (155 ºC) or customer specific design
Taps are available
Fiberglass resin spacers are used in order to provide ease of cooling
AN (air-natural) cooling method
|
 |
|
|
INSULATION . F class (155 ºC) film insulation or epoxy resin reinforced fiberglass. . Epoxy based paint & insulating varnish.
INSTALLATION The height and the diameter of the reactor can be adjusted to customer specific needs in order to meet unusual space requirements.
Complete installation guidelines are provided with the reactors in order to meet required magnetic clearances on close metallic structures. Each reactor is supplied with an INSTALLATION GUIDELINES that specifies minimum magnetic clearances for the reactor.
SUPPORT STANDS Aluminum, hot dip galvanized steel or concrete support stands are designed for specific applications.
LOSSES All Hilkar Electric reactors are computer designed in order to minimize investment and operating losses.
|
 |
|
|
TESTS All the routine tests are performed in accordance with EN 60289 or other standards depending on customer request. Type test reports are available on request. All the test reports are submitted to customer.
Basic testing program includes some or all of the following tests:
• Routine Tests (Inductance, Resistance, One Minute AC Insulation Voltage Withstand Test and Impulse Voltage Withstand Test) • Short Circuit Withstand Test • Temperature Rise Test • Sound Level Test • Seismic Test
|
|
|
|